Dataset Details

Data Set ID: RS04_91_a_5min_2015
Originator: Christopher Daly
Title: Reference Stand air and soil temperature network at the Andrews Experimental Forest from 01-Oct-2014 to 01-Oct-2015
Abstract: The current network of temperature measurement sites are designed to represent spatial variability of air and soil temperature in rugged mountain topography, and serve as second-level stations to capture specific microclimate temperatures in conjunction with a network of Benchmark Meteorological Stations (MS001). The air and soil thermograph network has been reduced from the historical network of 37 sites originally established. An original network of 19 sites (RS01-RS19) were established during the International Biome Program in the early 1970's. Emphasis on phenology, plant moisture stress, and leaf nutrient content led to extending this network of air and soil temperature measurement. A plant community classification system (Dyrness et al., 1971) was used as a primary means of stratification, and a set of permanent vegetation plots (Reference Stands) was installed to represent forest communities with distinct vegetation and hypothesized different environments (Dyrness et al., 1974). A thermograph network was installed within the reference stands in the early 1970's (Zobel et al., 1974), and vegetation standing crop, tree growth and mortality, and plant succession were also measured. The majority of these sites were established to monitor micro-meteorological data under the canopy. The purpose of this network was to provide air and soil temperature data for modeling photosynthesis, respiration, phenology, and decomposition, and to measure environmental gradients.
Key Words: Air temperature, Climate data, Climate/Meteorology, Ecosystem monitoring, Environmental indexes and variables, Meteorology, Microclimate, Moisture stress, Reference stands, Soil temperature, Succession, Temperature growth index, Dew point temperature, Disturbance, Primary production
Study Type: Monitoring
Study Period: 01-Oct-2014 to 01-Oct-2015
Bounding Box: West longitude:  unspecified
North latitude:  unspecified
East longitude:  unspecified
South latitude:  unspecified
Site References: RS04_91
Downloads:  Formats

Data Table:  RS04_91_a_5min_2015 (Main data table, 105121 records)

Access:  Public

Metadata:  Text (ESA FLED)

Data Files:  Spreadsheet (CSV Text) [12612kb], GCE Data Toolbox File [4597kb], Web Table (HTML text) [383kb]

Column List:

Column Name Units Type Description (show)
1 AIRTEMP_DMOVVAR_02_03 deg c floating-point D = M-N
2 Flag_AIRTEMP_DMOVVAR_02_03 none string QA/QC flags for D = M-N (flagging criteria, where "x" is AIRTEMP_DMOVVAR_02_03: )
3 AIRTEMP_MOVVAR_225_03 deg c floating-point N = movvar(a_225_03,300,'omitnan')
4 Flag_AIRTEMP_MOVVAR_225_03 none string QA/QC flags for N = movvar(a_225_03,300,'omitnan') (flagging criteria, where "x" is AIRTEMP_MOVVAR_225_03: )
5 AIRTEMP_MOVVAR_225_02 deg c floating-point M = movvar(a_225_02,300,'omitnan')
6 Flag_AIRTEMP_MOVVAR_225_02 none string QA/QC flags for M = movvar(a_225_02,300,'omitnan') (flagging criteria, where "x" is AIRTEMP_MOVVAR_225_02: )
7 AIRTEMP_DFDIFF_02_03 deg c floating-point dfd02_03 = fd_225_02-fd_225_03
8 Flag_AIRTEMP_DFDIFF_02_03 none string QA/QC flags for dfd02_03 = fd_225_02-fd_225_03 (flagging criteria, where "x" is AIRTEMP_DFDIFF_02_03: )
9 AIRTEMP_FDIFF_225_03 deg c floating-point fd_225_03 = [NaN; diff(a_225_03)]
10 Flag_AIRTEMP_FDIFF_225_03 none string QA/QC flags for fd_225_03 = [NaN; diff(a_225_03)] (flagging criteria, where "x" is AIRTEMP_FDIFF_225_03: )
11 AIRTEMP_FDIFF_225_02 deg c floating-point fd_225_02 = [NaN; diff(a_225_02)]
12 Flag_AIRTEMP_FDIFF_225_02 none string QA/QC flags for fd_225_02 = [NaN; diff(a_225_02)] (flagging criteria, where "x" is AIRTEMP_FDIFF_225_02: )
13 AIRTEMP_XDIFFS_02_03 deg c floating-point xd2_2 = abs(a_225_02-a_225_03)
14 Flag_AIRTEMP_XDIFFS_02_03 none string QA/QC flags for xd2_2 = abs(a_225_02-a_225_03) (flagging criteria, where "x" is AIRTEMP_XDIFFS_02_03: )
15 AIRTEMP_STDEV deg c floating-point STDEV = std([a_225_02,a_225_03],0,2)
16 Flag_AIRTEMP_STDEV none string QA/QC flags for STDEV = std([a_225_02,a_225_03],0,2) (flagging criteria, where "x" is AIRTEMP_STDEV: )
17 Site string Site code
18 Date serial date floating-point TmStamp
19 LOGGERID none integer Logger ID
20 PROGID none floating-point Program ID
21 AIRTEMP_MEAN_225_0_02 deg c floating-point Average air temperature
22 Flag_AIRTEMP_MEAN_225_0_02 none string QA/QC flags for Average air temperature (flagging criteria, where "x" is AIRTEMP_MEAN_225_0_02: x<=-35="I", x>50="I", x<-18="Q", x>45="Q", flag_valuechange(x,6.5,6.5,1) ="V", flag_valuechange(x,8,8,1) ="I", isnan(x)="M", x<FOURLO="Q", x>FOURHI="Q")
23 AIRTEMP_MEAN_225_0_03 deg c floating-point Average air temperature
24 Flag_AIRTEMP_MEAN_225_0_03 none string QA/QC flags for Average air temperature (flagging criteria, where "x" is AIRTEMP_MEAN_225_0_03: x<=-35="I", x>50="I", x<-18="Q", x>45="Q", flag_valuechange(x,6.5,6.5,1) ="V", flag_valuechange(x,8,8,1) ="I", isnan(x)="M", x<FOURLO="Q", x>FOURHI="Q")
25 AIRTEMP_MAX_225_0_02 deg c floating-point Maximum air temperature
26 Flag_AIRTEMP_MAX_225_0_02 none string QA/QC flags for Maximum air temperature (flagging criteria, where "x" is AIRTEMP_MAX_225_0_02: x<=-35="I", x>50="I", x<-18="Q", x>45="Q", flag_valuechange(x,6.5,6.5,1) ="V", flag_valuechange(x,8,8,1) ="I", isnan(x)="M", x<FOURLO="Q", x>FOURHI="Q")
27 AIRTEMP_MAX_225_0_03 deg c floating-point Maximum air temperature
28 Flag_AIRTEMP_MAX_225_0_03 none string QA/QC flags for Maximum air temperature (flagging criteria, where "x" is AIRTEMP_MAX_225_0_03: x<=-35="I", x>50="I", x<-18="Q", x>45="Q", flag_valuechange(x,6.5,6.5,1) ="V", flag_valuechange(x,8,8,1) ="I", isnan(x)="M", x<FOURLO="Q", x>FOURHI="Q")
29 AIRTEMP_MIN_225_0_02 deg c floating-point Minimum air temperature
30 Flag_AIRTEMP_MIN_225_0_02 none string QA/QC flags for Minimum air temperature (flagging criteria, where "x" is AIRTEMP_MIN_225_0_02: x<=-35="I", x>50="I", x<-18="Q", x>45="Q", flag_valuechange(x,6.5,6.5,1) ="V", flag_valuechange(x,8,8,1) ="I", isnan(x)="M", x<FOURLO="Q", x>FOURHI="Q")
31 AIRTEMP_MIN_225_0_03 deg c floating-point Minimum air temperature
32 Flag_AIRTEMP_MIN_225_0_03 none string QA/QC flags for Minimum air temperature (flagging criteria, where "x" is AIRTEMP_MIN_225_0_03: x<=-35="I", x>50="I", x<-18="Q", x>45="Q", flag_valuechange(x,6.5,6.5,1) ="V", flag_valuechange(x,8,8,1) ="I", isnan(x)="M", x<FOURLO="Q", x>FOURHI="Q")
33 SOILTEMP_MEAN_0_10_01 deg c floating-point Average soil temperature
34 Flag_SOILTEMP_MEAN_0_10_01 none string QA/QC flags for Average soil temperature (flagging criteria, where "x" is SOILTEMP_MEAN_0_10_01: x<-2="I", x>35="I", x<-1="Q", x>30="Q", isnan(x)="M")
35 SOILTEMP_MEAN_0_20_02 deg c floating-point Average soil temperature
36 Flag_SOILTEMP_MEAN_0_20_02 none string QA/QC flags for Average soil temperature (flagging criteria, where "x" is SOILTEMP_MEAN_0_20_02: x<-2="I", x>35="I", x<-1="Q", x>30="Q", isnan(x)="M")
37 SOILTEMP_MEAN_0_30_03 deg c floating-point Average soil temperature
38 Flag_SOILTEMP_MEAN_0_30_03 none string QA/QC flags for Average soil temperature (flagging criteria, where "x" is SOILTEMP_MEAN_0_30_03: x<-2="I", x>35="I", x<-1="Q", x>30="Q", isnan(x)="M")
39 BATTERY_INST_0_0_01 volts floating-point Battery supply voltage
40 Flag_BATTERY_INST_0_0_01 none string QA/QC flags for Battery supply voltage (flagging criteria, where "x" is BATTERY_INST_0_0_01: x<0="I", x<12="L", x>15="H", isnan(x)="M")
41 AIRTEMP_CHECK_225_0_03 deg c floating-point Average air temperature manual sample
42 Flag_AIRTEMP_CHECK_225_0_03 none string QA/QC flags for Average air temperature manual sample (flagging criteria, where "x" is AIRTEMP_CHECK_225_0_03: x<=-35="I", x>50="I", x<-18="Q", x>45="Q", x<FOURLO="Q", x>FOURHI="Q")
43 SOILTEMP_CHECK_0_10_01 deg c floating-point Average soil temperature manual check
44 Flag_SOILTEMP_CHECK_0_10_01 none string QA/QC flags for Average soil temperature manual check (flagging criteria, where "x" is SOILTEMP_CHECK_0_10_01: x<-2="I", x>35="I", x<-1="Q", x>30="Q")
45 BATTERY_CHECK_0_0_01 volts floating-point Battery supply voltage manual check
46 Flag_BATTERY_CHECK_0_0_01 none string QA/QC flags for Battery supply voltage manual check (flagging criteria, where "x" is BATTERY_CHECK_0_0_01: x<0="I", x<12="L", x>15="H")
Last Modified: 18-Apr-2018 02:00:07