| Column |
Name |
Units |
Type |
Description (show)
|
| 1 |
DataSetName |
none |
string |
Names of the original data sets merged to create the composite data set |
| 2 |
Site |
|
string |
Site code |
| 3 |
Date |
|
string |
Calendar date and time of measurement |
| 4 |
SiteID |
|
floating-point |
SiteID |
| 5 |
Flag_SiteID |
none |
string |
QA/QC flags for SiteID (flagging criteria, where "x" is SiteID: ) |
| 6 |
LOGGERID |
none |
integer |
Logger ID |
| 7 |
PROGID |
none |
floating-point |
Program ID |
| 8 |
VNOTCH_INST_0_0_01 |
none |
integer |
Binary indicator for V-notch. 1 = on, 0 = off |
| 9 |
Flag_VNOTCH_INST_0_0_01 |
none |
string |
QA/QC flags for Binary indicator for V-notch. 1 = on, 0 = off (flagging criteria, where "x" is VNOTCH_INST_0_0_01: x>1="I", x<0="I") |
| 10 |
STAGE_INST_0_0_01 |
ft |
floating-point |
Stage height |
| 11 |
Flag_STAGE_INST_0_0_01 |
none |
string |
QA/QC flags for Stage height (flagging criteria, where "x" is STAGE_INST_0_0_01: isnan(x)="M") |
| 12 |
ECD_INST_0_0_01 |
microS/cm |
floating-point |
Stream specific conductance |
| 13 |
Flag_ECD_INST_0_0_01 |
none |
string |
QA/QC flags for Stream specific conductance (flagging criteria, where "x" is ECD_INST_0_0_01: x<=5="I", x>=7000="I", isnan(x)="M", Date>=datenum("11/28/2020 06:25:00")&Date<=datenum("12/03/2020 12:00:00")="I", manual) |
| 14 |
WATERTEMP_INST_0_0_01 |
deg c |
floating-point |
Average temperature of water from EC |
| 15 |
Flag_WATERTEMP_INST_0_0_01 |
none |
string |
QA/QC flags for Average temperature of water from EC (flagging criteria, where "x" is WATERTEMP_INST_0_0_01: x<-2="I", x>30="I", x<-1="Q", x>21="Q", isnan(x)="M", x<water_FOURLO="Q", x>water_FOURHI="Q") |
| 16 |
AIRTEMP_MEAN_240_0_01 |
deg c |
floating-point |
Average air temperature |
| 17 |
Flag_AIRTEMP_MEAN_240_0_01 |
none |
string |
QA/QC flags for Average air temperature (flagging criteria, where "x" is AIRTEMP_MEAN_240_0_01: x<-35="I", x>55="I", isnan(x)="M", (AIRTEMP_MAX_240_0_01-AIRTEMP_MEAN_240_0_01)>1="Q", (AIRTEMP_MEAN_240_0_01-AIRTEMP_MIN_240_0_01)>1="Q", x>AIRTEMP_MAX_240_0_01="I", x<AIRTEMP_MIN_240_0_01=‘I’) |
| 18 |
AIRTEMP_MAX_240_0_01 |
deg c |
floating-point |
Maximum air temperature (240) |
| 19 |
Flag_AIRTEMP_MAX_240_0_01 |
none |
string |
QA/QC flags for Maximum air temperature (240) (flagging criteria, where "x" is AIRTEMP_MAX_240_0_01: x<-35="I", x>55="I", isnan(x)="M", x<air_FOURLO="Q", x>air_FOURHI="Q", manual) |
| 20 |
AIRTEMP_MIN_240_0_01 |
deg c |
floating-point |
Minimum air temperature (240) |
| 21 |
Flag_AIRTEMP_MIN_240_0_01 |
none |
string |
QA/QC flags for Minimum air temperature (240) (flagging criteria, where "x" is AIRTEMP_MIN_240_0_01: x<-35="I", x>55="I", isnan(x)="M", x<air_FOURLO="Q", x>air_FOURHI="Q", manual) |
| 22 |
WATERTEMP_MEAN_0_0_01 |
deg c |
floating-point |
Average water temperature from EC |
| 23 |
Flag_WATERTEMP_MEAN_0_0_01 |
none |
string |
QA/QC flags for Average water temperature from EC (flagging criteria, where "x" is WATERTEMP_MEAN_0_0_01: x<-2="I", x>30="I", x<-1="Q", x>21="Q", isnan(x)="M", (WATERTEMP_MAX_0_0_01-WATERTEMP_MEAN_0_0_01)>1="Q", (WATERTEMP_MEAN_0_0_01-WATERTEMP_MIN_0_0_01)>1="Q", x>WATERTEMP_MAX_0_0_01="I", x<WATERTEMP_MIN_0_0_01="I", manual) |
| 24 |
WATERTEMP_MAX_0_0_01 |
deg c |
floating-point |
Maximum water temperature from EC |
| 25 |
Flag_WATERTEMP_MAX_0_0_01 |
none |
string |
QA/QC flags for Maximum water temperature from EC (flagging criteria, where "x" is WATERTEMP_MAX_0_0_01: x<-2="I", x>30="I", x<-1="Q", x>21="Q", isnan(x)="M", x<water_FOURLO="Q", x>water_FOURHI="Q", manual) |
| 26 |
WATERTEMP_MIN_0_0_01 |
deg c |
floating-point |
Minimum water temperature from EC |
| 27 |
Flag_WATERTEMP_MIN_0_0_01 |
none |
string |
QA/QC flags for Minimum water temperature from EC (flagging criteria, where "x" is WATERTEMP_MIN_0_0_01: x<-2="I", x>30="I", x<-1="Q", x>21="Q", isnan(x)="M", x<water_FOURLO="Q", x>water_FOURHI="Q", manual) |
| 28 |
BATTERY_INST_0_0_01 |
volts |
floating-point |
Battery supply level |
| 29 |
Flag_BATTERY_INST_0_0_01 |
none |
string |
QA/QC flags for Battery supply level (flagging criteria, where "x" is BATTERY_INST_0_0_01: x<0="I", x<12="L", x>15="H", isnan(x)="M") |
| 30 |
air_FOURLO |
deg c |
floating-point |
Air temperature 4*std lower of mean air temperature |
| 31 |
Flag_air_FOURLO |
none |
string |
QA/QC flags for Air temperature 4*std lower of mean air temperature (flagging criteria, where "x" is air_FOURLO: ) |
| 32 |
air_FOURHI |
deg c |
floating-point |
Air temperature 4*std greater than mean air temperature |
| 33 |
Flag_air_FOURHI |
none |
string |
QA/QC flags for Air temperature 4*std greater than mean air temperature (flagging criteria, where "x" is air_FOURHI: ) |
| 34 |
water_FOURLO |
deg c |
floating-point |
Water temperature 4*std lower than mean water temperature |
| 35 |
Flag_water_FOURLO |
none |
string |
QA/QC flags for Water temperature 4*std lower than mean water temperature (flagging criteria, where "x" is water_FOURLO: ) |
| 36 |
water_FOURHI |
deg c |
floating-point |
Water temperature 4*std greater than mean water temperature |
| 37 |
Flag_water_FOURHI |
none |
string |
QA/QC flags for Water temperature 4*std greater than mean water temperature (flagging criteria, where "x" is water_FOURHI: ) |