Downloads:
|
Data Table: gsws01_115_sys_2019 (Main data table, 66 records)
Access: Public
Metadata: Text (ESA FLED)
Data Files:
Spreadsheet (CSV Text) [13kb], GCE Data Toolbox File [10kb], Web Table (HTML text) [39kb]
Column List:
Column |
Name |
Units |
Type |
Description (show)
|
1 |
Site |
|
string |
Site code |
2 |
Date |
|
string |
Calendar date and time of measurement |
3 |
RecNum |
count |
integer |
RecNum |
4 |
SiteID |
|
floating-point |
SiteID |
5 |
Flag_SiteID |
none |
string |
QA/QC flags for SiteID (flagging criteria, where "x" is SiteID: ) |
6 |
LOGGERID |
none |
integer |
Logger ID |
7 |
PROGID |
none |
floating-point |
Program ID |
8 |
SITE_VISIT |
number |
integer |
Did you visit the site? (1 = yes) |
9 |
Flag_SITE_VISIT |
none |
string |
QA/QC flags for Did you visit the site? (1 = yes) (flagging criteria, where "x" is SITE_VISIT: flag_notinarray(x,[NAN,1])="Q") |
10 |
EC_BRUSH |
number |
integer |
Did you brush the EC probe? (1 = yes) |
11 |
Flag_EC_BRUSH |
none |
string |
QA/QC flags for Did you brush the EC probe? (1 = yes) (flagging criteria, where "x" is EC_BRUSH: flag_notinarray(x,[NAN,1])="Q", isnan(x)="M") |
12 |
STAGE_RESET |
number |
integer |
Did you reset the PAT? (1 = yes) |
13 |
Flag_STAGE_RESET |
none |
string |
QA/QC flags for Did you reset the PAT? (1 = yes) (flagging criteria, where "x" is STAGE_RESET: flag_notinarray(x,[NAN,1])="Q", isnan(x)="M") |
14 |
WATER_SAMP |
HHMM |
integer |
Time water sample collected |
15 |
Flag_WATER_SAMP |
none |
string |
QA/QC flags for Time water sample collected (flagging criteria, where "x" is WATER_SAMP: x<0="Q", x>2400="Q", isnan(x)="M") |
16 |
STAGE_HG |
ft |
floating-point |
Hook gauge reading (0.000 ft) |
17 |
Flag_STAGE_HG |
none |
string |
QA/QC flags for Hook gauge reading (0.000 ft) (flagging criteria, where "x" is STAGE_HG: isnan(x)="M") |
18 |
STAGE_INST_0_0_01 |
ft |
floating-point |
Stage height |
19 |
Flag_STAGE_INST_0_0_01 |
none |
string |
QA/QC flags for Stage height (flagging criteria, where "x" is STAGE_INST_0_0_01: isnan(x)="M", flag_daterange(Date,{"07/17/2021 15:15:00","07/19/2021 15:40:00"})="Q", flag_daterange(Date,{"08/17/2021 11:25:00","08/24/2021 14:00:00"})="Q", flag_daterange(Date,{"06/18/2020 11:35:00","06/23/2020 07:50:00"})="Q", flag_daterange(Date,{"10/08/2024 07:55:00","10/15/2024 15:30:00"})="Q") |
20 |
AIRTEMP_CHECK_150_0_01 |
deg c |
floating-point |
Manual air temperature check |
21 |
Flag_AIRTEMP_CHECK_150_0_01 |
none |
string |
QA/QC flags for Manual air temperature check (flagging criteria, where "x" is AIRTEMP_CHECK_150_0_01: x<-35="I", x>55="I", isnan(x)="M") |
22 |
AIRTEMP_MEAN_150_0_01 |
deg c |
floating-point |
Average air temperature (305) |
23 |
Flag_AIRTEMP_MEAN_150_0_01 |
none |
string |
QA/QC flags for Average air temperature (305) (flagging criteria, where "x" is AIRTEMP_MEAN_150_0_01: x<-35="I", x>55="I", isnan(x)="M", x<air_FOURLO="Q", x>air_FOURHI="Q", (AIRTEMP_MAX_150_0_01-AIRTEMP_MEAN_150_0_01)>1="Q", (AIRTEMP_MEAN_150_0_01-AIRTEMP_MIN_150_0_01)>1="Q", x>AIRTEMP_MAX_150_0_01="I", x<AIRTEMP_MIN_150_0_01=‘I’) |
24 |
EC_CHECK |
uS/cm |
floating-point |
Manual EC check |
25 |
Flag_EC_CHECK |
none |
string |
QA/QC flags for Manual EC check (flagging criteria, where "x" is EC_CHECK: isnan(x)="M") |
26 |
EC_INST_0_0_01 |
microS/cm |
floating-point |
Conductivity |
27 |
Flag_EC_INST_0_0_01 |
none |
string |
QA/QC flags for Conductivity (flagging criteria, where "x" is EC_INST_0_0_01: x<=5="I", x>=7000="I", isnan(x)="M", Date>=datenum("10/1/2015 12:00:00")&Date<=datenum("11/6/2015 12:00:00")="Q", Date>=datenum("04/15/2016 18:10:00")&Date<=datenum("04/18/2016 12:00:00")="X") |
28 |
WATERTEMP_CHECK_0_0_01 |
deg c |
floating-point |
Manual Water Temperature check |
29 |
Flag_WATERTEMP_CHECK_0_0_01 |
none |
string |
QA/QC flags for Manual Water Temperature check (flagging criteria, where "x" is WATERTEMP_CHECK_0_0_01: x<-2="I", x>30="I", x<-1="Q", x>21="Q", isnan(x)="M") |
30 |
WATERTEMP_INST_0_0_01 |
deg c |
floating-point |
Instantaneous temperature of water from EC |
31 |
Flag_WATERTEMP_INST_0_0_01 |
none |
string |
QA/QC flags for Instantaneous temperature of water from EC (flagging criteria, where "x" is WATERTEMP_INST_0_0_01: x<-2="I", x>30="I", x<-1="Q", x>21="Q", isnan(x)="M", x<water_FOURLO="Q", x>water_FOURHI="Q", Date>=datenum("10/1/2015 12:00:00")&Date<=datenum("11/6/2015 12:00:00")="Q", Date>=datenum("7/30/2020 16:00:00")&Date<=datenum("08/17/2020 16:35:00")="Q", (WATERTEMP_MAX_0_0_01-WATERTEMP_INST_0_0_01)>0.5="Q", (WATERTEMP_INST_0_0_01-WATERTEMP_MIN_0_0_01)>0.5="Q", x>WATERTEMP_MAX_0_0_01="I", x<WATERTEMP_MIN_0_0_01=‘I’) |
32 |
VNOTCH_INST_0_0_01 |
number |
integer |
Binary indicator for V-notch. 1 = on, 0 = off |
33 |
Flag_VNOTCH_INST_0_0_01 |
none |
string |
QA/QC flags for Binary indicator for V-notch. 1 = on, 0 = off (flagging criteria, where "x" is VNOTCH_INST_0_0_01: x>1="Q", x<0="Q",flag_notinarray(x,[0,1])="Q") |
34 |
STAGE_HGTM |
|
floating-point |
STAGE_HGTM |
35 |
Flag_STAGE_HGTM |
none |
string |
QA/QC flags for STAGE_HGTM (flagging criteria, where "x" is STAGE_HGTM: ) |
|