Dataset Details

Data Set ID: phrsc_15min_2013
Originator: Chris Daly
Title: Primet Horizontal Radiation Shield Comparison
Abstract: The Primet Horizontal Radiation Shield Comparison (PHRSC) measures the temperature difference between a reference temperature sensor inside a fan aspirated radiation shield and temperature sensors located inside passively aspirated radiation shields. Displayed data are statistics over 15 minute time periods. Observered variables include air temperature, wind speed and direction, and short and longwave radiation.
Key Words:
Study Type: Monitoring
Study Period: 01-Oct-2012 to 01-Oct-2013
Bounding Box: West longitude:  unspecified
North latitude:  unspecified
East longitude:  unspecified
South latitude:  unspecified
Site References: PHRSC
Downloads:  Formats

Data Table:  phrsc_15min_2013 (Main data table, 35041 records)

Access:  Public

Metadata:  Text (ESA FLED)

Data Files:  Spreadsheet (CSV Text) [4485kb], GCE Data Toolbox File [1030kb], Web Table (HTML text) [302kb]

Column List:

Column Name Units Type Description (show)
1 Site string Site code
2 Date serial date floating-point TmStamp
3 RMY_ASP_Avg deg c floating-point Averaged measurement of RMY_ASP_Avg
4 Flag_RMY_ASP_Avg none string QA/QC flags for Averaged measurement of RMY_ASP_Avg (flagging criteria, where "x" is RMY_ASP_Avg: isnan(x)="M", x<=-35="I", x>50="I", x<-18="Q", x>45="Q", x<FOURLO="Q", x>FOURHI="Q", flag_valuechange(x,8,8,1)="I", flag_valuechange(x,6.5,6.5,1)="V", Date>=datenum("08/02/2016 18:45:00")&Date<=datenum("08/31/2016 20:00:00")="T")
5 Cotton_Avg deg c floating-point Averaged measurement of Cotton_Avg
6 Flag_Cotton_Avg none string QA/QC flags for Averaged measurement of Cotton_Avg (flagging criteria, where "x" is Cotton_Avg: isnan(x)="M", x<=-35="I", x>50="I", x<-18="Q", x>45="Q", x<FOURLO="Q", x>FOURHI="Q", flag_valuechange(x,8,8,1)="I", flag_valuechange(x,6.5,6.5,1)="V")
7 Gill_Sh_Avg deg c floating-point Averaged measurement of Gill_Lg_Avg
8 Flag_Gill_Sh_Avg none string QA/QC flags for Averaged measurement of Gill_Lg_Avg (flagging criteria, where "x" is Gill_Sh_Avg: isnan(x)="M", x<=-35="I", x>50="I", x<-18="Q", x>45="Q", x<FOURLO="Q", x>FOURHI="Q", flag_valuechange(x,8,8,1)="I", flag_valuechange(x,6.5,6.5,1)="V")
9 HJA_Sh_Avg deg c floating-point Averaged measurement of HJA_Sh_Avg
10 Flag_HJA_Sh_Avg none string QA/QC flags for Averaged measurement of HJA_Sh_Avg (flagging criteria, where "x" is HJA_Sh_Avg: isnan(x)="M", x<=-35="I", x>50="I", x<-18="Q", x>45="Q", x<FOURLO="Q", x>FOURHI="Q", flag_valuechange(x,8,8,1)="I", flag_valuechange(x,6.5,6.5,1)="V")
11 Gill_Lg_Avg deg c floating-point Averaged measurement of Gill_Lg_Avg
12 Flag_Gill_Lg_Avg none string QA/QC flags for Averaged measurement of Gill_Lg_Avg (flagging criteria, where "x" is Gill_Lg_Avg: isnan(x)="M", x<=-35="I", x>50="I", x<-18="Q", x>45="Q", x<FOURLO="Q", x>FOURHI="Q", flag_valuechange(x,8,8,1)="I", flag_valuechange(x,6.5,6.5,1)="V")
13 HJA_Lg_Avg deg c floating-point Averaged measurement of HJA_Lg_Avg
14 Flag_HJA_Lg_Avg none string QA/QC flags for Averaged measurement of HJA_Lg_Avg (flagging criteria, where "x" is HJA_Lg_Avg: isnan(x)="M", x<=-35="I", x>50="I", x<-18="Q", x>45="Q", x<FOURLO="Q", x>FOURHI="Q", flag_valuechange(x,8,8,1)="I", flag_valuechange(x,6.5,6.5,1)="V")
15 Gill_AF_Avg deg c floating-point Averaged measurement of Gill_Sh_Avg
16 Flag_Gill_AF_Avg none string QA/QC flags for Averaged measurement of Gill_Sh_Avg (flagging criteria, where "x" is Gill_AF_Avg: isnan(x)="M", x<=-35="I", x>50="I", x<-18="Q", x>45="Q", x<FOURLO="Q", x>FOURHI="Q", flag_valuechange(x,8,8,1)="I", flag_valuechange(x,6.5,6.5,1)="V")
17 CM3_Up_Avg w m-2 floating-point Upward facing sensor that measures down-welling solar radiation
18 Flag_CM3_Up_Avg none string QA/QC flags for Upward facing sensor that measures down-welling solar radiation (flagging criteria, where "x" is CM3_Up_Avg: isnan(x)="M", x>2000="I", x<-2000="I", x>1060="Q")
19 CM3_Dn_Avg w m-2 floating-point Downward facing sensor that measures up-welling solar radiation
20 Flag_CM3_Dn_Avg none string QA/QC flags for Downward facing sensor that measures up-welling solar radiation (flagging criteria, where "x" is CM3_Dn_Avg: isnan(x)="M")
21 WINDSP_AVG m s-1 floating-point Averaged measurement of WindSp_Avg
22 Flag_WINDSP_AVG none string QA/QC flags for Averaged measurement of WindSp_Avg (flagging criteria, where "x" is WINDSP_AVG: x<=0.3="N", x<=1="B", x>20="I", x>15="Q", isnan(x)="M")
23 WINDDIR_AVG degrees floating-point Instantaneous measurement of WindDir
24 Flag_WINDDIR_AVG none string QA/QC flags for Instantaneous measurement of WindDir (flagging criteria, where "x" is WINDDIR_AVG: isnan(x)="M", x<0="I", x>360="I", WINDSP_AVG=0="I")
Last Modified: 20-Jun-2018 04:32:37