I. Data Set Descriptors A. Title: Gaging station system data. Usage: Manually entered in-field data and post collection calibration from 26-Jul-2018 to 25-Sep-2018 B. Accession Number: C. Description 1. Originator(s): Sherri L. Johnson 2. Abstract: Stream temperature at stream gages and air temperature above the stream are measured at all stream gaging sites and at selected major stream confluences. Current temperature data are collected as hourly averages of instantaneous measurements. these data began ~1996. Historic data, starting in 1950 at Lookout Creek gage, are included at daily mean or maximum and minimum. 3. Study Type: 4. Study Themes: 5. LTER Core Areas: 6. Georeferences: 7. Submission Date: D. Keywords: II. Research Origin Descriptors A. Overall Project Description 1. Project Title: 2. Principal Investigators: Stanley V. Gregory, Christopher Daly, Randall C. Wildman, Julia A. Jones, Jeffrey J. McDonnell 3. Funding Period: to 4. Objectives: 5. Abstract: 6. Funding Source: B. Sub-project Description 1. Site Description a. Geographic Location: Coordinates: b. Physiographic Region: c. Landform Components: d. Hydrographic Characteristics: e. Topographic Attributes: f. Geology, Lithology and Soils: g. Vegetation Communities: h. History of Land Use and Disturbance: i. Climate: 2. Experimental or Sampling Design a. Design Characteristics: b. Permanent Plots: c. Data Collection Duration and Frequency: Beginning of Observations: End of Observations: 3. Research Methods a. Field and Laboratory Methods: b. Protocols: c. Instrumentation: d. Taxonomy and Systematics: e. Speclies List: f. Permit History: 4. Project Personnel a. Personnel: b. Affiliations: III. Data Set Status and Accessibility A. Status 1. Latest Update: 07-Jan-2024 2. Latest Archive Date: 3. Latest Metadata Update: 07-Jan-2024 4. Data Verification Status: B. Accessibility 1. Storage Location and Medium: Stored at on media: 2. Contact Person: Name: Position: Organization: Address: City: State: Postal Code: Phone: Email: UserID: 3. Copyright Restrictions: 4. Restrictions: a. Release Date: Affiliates: , Public: b. Citation: c. Disclaimer: 5. Costs: IV. Data Structural Descriptors A. Data Set File 1. File Name: gsws01_115_sys_2018.csv 2. Size: 20 records 3. File Format: ASCII text (comma-separated value format) 3a. Delimiters: single comma 4. Header Information: 5 lines of ASCII text 5. Alphanumeric Attributes: 6. Quality Control Flag Codes: Q = questionable value, I = invalid value (out of range), H = unspecified 7. Authentication Procedures: 8. Calculations: EC_INST_0_0_01: EC_INST_0_0_01(microS/cm) = EC_INST_0_0_01(cmS cm^-1)*1000 9. Processing History: Software version: GCE Data Toolbox Version 3.9.10 (23-May-2022) Data structure version: GCE Data Structure 1.1 (29-Mar-2001) Original data file processed: metdat query: SELECT * FROM WS01_115_SYS WHERE LOGGERID = 115 AND TmStamp BETWEEN '2017-10-01 00:05:00.0' AND '2018-10-01 00:00:00.0' ORDER BY TmStamp ASC (20 records) Data processing history: 07-Jan-2024: new GCE Data Structure 1.1 created ('newstruct') 07-Jan-2024: imported result set from SQL query on data source 'metdat' ('sql2struct') 07-Jan-2024: imported all documentation metadata from the template 'LNDB_GsWS01_3', updating descriptors for columns Date, RecNum, SiteID, LOGGERID, PROGID, SITE_VISIT, EC_BRUSH, STAGE_RESET, WATER_SAMP, STAGE_HG, STAGE_INST_0_0_01, AIRTEMP_CHECK_150_0_01, AIRTEMP_MEAN_150_0_01, EC_CHECK, EC_INST_0_0_01, WATERTEMP_CHECK_0_0_01, WATERTEMP_INST_0_0_01 and VNOTCH_INST_0_0_01 ('meta_template') 07-Jan-2024: updated 6 metadata fields in the Data, Dataset, Project, Status section(s) ('addmeta') 07-Jan-2024: updated title ('newtitle') 07-Jan-2024: Q/C flagging criteria applied, 'flags' field updated ('dataflag') 07-Jan-2024: Name of column TmStamp changed to Date; Name of column LoggerID changed to LOGGERID; Name of column ProgID changed to PROGID; Name of column STAGE_HOOK changed to STAGE_HG; Name of column STAGE changed to STAGE_INST_0_0_01; Name of column AIRTEMP_CHECK changed to AIRTEMP_CHECK_150_0_01; Name of column AIR_TEMP_Avg changed to AIRTEMP_MEAN_150_0_01; Name of column C25mScm_1 changed to EC_INST_0_0_01; Name of column WATERTEMP_CHECK changed to WATERTEMP_CHECK_0_0_01; Name of column CDH2O_TMP changed to WATERTEMP_INST_0_0_01; Name of column V_NOTCH_WEIR changed to VNOTCH_INST_0_0_01; ('apply_template') 07-Jan-2024: Units of column Date changed from '' to 'serial number'; Units of column RecNum changed from '' to 'count'; Units of column LOGGERID changed from '' to 'none'; Units of column PROGID changed from '' to 'none'; Units of column SITE_VISIT changed from '' to 'number'; Units of column EC_BRUSH changed from '' to 'number'; Units of column STAGE_RESET changed from '' to 'number'; Units of column WATER_SAMP changed from '' to 'HHMM'; Units of column STAGE_HG changed from '' to 'ft'; Units of column STAGE_INST_0_0_01 changed from '' to 'ft'; Units of column AIRTEMP_CHECK_150_0_01 changed from '' to 'deg c'; Units of column AIRTEMP_MEAN_150_0_01 changed from '' to 'deg c'; Units of column EC_CHECK changed from '' to 'uS/cm'; Units of column EC_INST_0_0_01 changed from '' to 'cmS cm^-1'; Units of column WATERTEMP_CHECK_0_0_01 changed from '' to 'deg c'; Units of column WATERTEMP_INST_0_0_01 changed from '' to 'deg c'; Units of column VNOTCH_INST_0_0_01 changed from '' to 'number'; ('apply_template') 07-Jan-2024: Data Type of column LOGGERID changed from 'f' to 'd'; Data Type of column PROGID changed from 'd' to 'f'; Data Type of column SITE_VISIT changed from 'f' to 'd'; Data Type of column EC_BRUSH changed from 'f' to 'd'; Data Type of column STAGE_RESET changed from 'f' to 'd'; Data Type of column WATER_SAMP changed from 'f' to 'd'; Data Type of column VNOTCH_INST_0_0_01 changed from 'f' to 'd'; ('apply_template') 07-Jan-2024: Variable Type of column RecNum changed from 'data' to 'nominal'; Variable Type of column LOGGERID changed from 'data' to 'nominal'; Variable Type of column PROGID changed from 'data' to 'nominal'; ('apply_template') 07-Jan-2024: Numeric Type of column SiteID changed from 'continous' to 'unspecified'; Numeric Type of column LOGGERID changed from 'continous' to 'discrete'; Numeric Type of column PROGID changed from 'discrete' to 'continuous'; Numeric Type of column SITE_VISIT changed from 'continous' to 'discrete'; Numeric Type of column EC_BRUSH changed from 'continous' to 'discrete'; Numeric Type of column STAGE_RESET changed from 'continous' to 'discrete'; Numeric Type of column WATER_SAMP changed from 'continous' to 'discrete'; Numeric Type of column STAGE_HG changed from 'continous' to 'continuous'; Numeric Type of column STAGE_INST_0_0_01 changed from 'continous' to 'continuous'; Numeric Type of column AIRTEMP_CHECK_150_0_01 changed from 'continous' to 'continuous'; Numeric Type of column AIRTEMP_MEAN_150_0_01 changed from 'continous' to 'continuous'; Numeric Type of column EC_CHECK changed from 'continous' to 'continuous'; Numeric Type of column EC_INST_0_0_01 changed from 'continous' to 'continuous'; Numeric Type of column WATERTEMP_CHECK_0_0_01 changed from 'continous' to 'continuous'; Numeric Type of column WATERTEMP_INST_0_0_01 changed from 'continous' to 'continuous'; Numeric Type of column VNOTCH_INST_0_0_01 changed from 'continous' to 'discrete'; ('apply_template') 07-Jan-2024: Q/C Criteria of column Date changed from '' to 'x<0='I''; Q/C Criteria of column RecNum changed from '' to 'x<0='I''; Q/C Criteria of column LOGGERID changed from '' to 'flag_notinarray(x,[101,115])='I''; Q/C Criteria of column PROGID changed from '' to 'flag_valuechange(x,0.1,0.1,1)='P''; Q/C Criteria of column SITE_VISIT changed from '' to 'flag_notinarray(x,[NAN,1])='Q''; Q/C Criteria of column EC_BRUSH changed from '' to 'flag_notinarray(x,[NAN,1])='Q';isnan(x)='M''; Q/C Criteria of column STAGE_RESET changed from '' to 'flag_notinarray(x,[NAN,1])='Q';isnan(x)='M''; Q/C Criteria of column WATER_SAMP changed from '' to 'x<0='Q';x>2400='Q';isnan(x)='M''; Q/C Criteria of column STAGE_HG changed from '' to 'isnan(x)='M''; Q/C Criteria of column STAGE_INST_0_0_01 changed from '' to 'isnan(x)='M';flag_daterange(col_Date,{'07/17/2021 15:15:00','07/19/2021 15:40:00'})='Q';flag_daterange(col_Date,{'08/17/2021 11:25:00','08/24/2021 14:00:00'})='Q';flag_daterange(col_Date,{'06/18/2020 11:35:00','06/23/2020 07:50:00'})='Q''; Q/C Criteria of column AIRTEMP_CHECK_150_0_01 changed from '' to 'x<-35='I';x>55='I';isnan(x)='M''; Q/C Criteria of column AIRTEMP_MEAN_150_0_01 changed from '' to 'x<-35='I';x>55='I';isnan(x)='M';xcol_air_FOURHI='Q';(col_AIRTE MP_MAX_150_0_01-col_AIRTEMP_MEAN_150_0_01)>1='Q'; (col_AIRTEMP_MEAN_150_0_01-col_AIRTEMP_MIN_150_0_01)>1='Q'; x>col_AIRTEMP_MAX_150_0_01='I'; x=7.0='I';isnan(x)='M';col_Date>=datenum('10/1/2015 12:00:00')&col_Date<=datenum('11/6/2015 12:00:00')='Q';col_Date>=datenum('04/15/2016 18:10:00')&col_Date<=datenum('04/18/2016 12:00:00')='X''; Q/C Criteria of column WATERTEMP_CHECK_0_0_01 changed from '' to 'x<-2='I';x>30='I';x<-1='Q';x>21='Q';isnan(x)='M''; Q/C Criteria of column WATERTEMP_INST_0_0_01 changed from '' to 'x<-2='I';x>30='I';x<-1='Q';x>21='Q';isnan(x)='M';xcol_water_ FOURHI='Q';col_Date>=datenum('10/1/2015 12:00:00')&col_Date<=datenum('11/6/2015 12:00:00')='Q';col_Date>=datenum('7/30/2020 16:00:00')&col_Date<=datenum('08/17/2020 16:35:00')='Q';(col_WATERTEMP_MAX_0_0_01-col_WATERTEMP_INST_0_0_01)>0.5='Q'; (col_WATERTEMP_INST_0_0_01-col_WATERTEMP_MIN_0_0_01)>0.5='Q'; x>col_WATERTEMP_MAX_0_0_01='I'; x1='Q';x<0='Q',flag_notinarray(x,[0,1])='Q''; ('apply_template') 07-Jan-2024: Precision of column Date changed from 0 to 7; Precision of column LOGGERID changed from 2 to 0; Precision of column PROGID changed from 0 to 1; Precision of column SITE_VISIT changed from 5 to 0; Precision of column EC_BRUSH changed from 5 to 0; Precision of column STAGE_RESET changed from 5 to 0; Precision of column WATER_SAMP changed from 1 to 0; Precision of column STAGE_HG changed from 5 to 4; Precision of column STAGE_INST_0_0_01 changed from 5 to 4; Precision of column AIRTEMP_CHECK_150_0_01 changed from 3 to 2; Precision of column EC_CHECK changed from 2 to 4; Precision of column EC_INST_0_0_01 changed from 6 to 4; Precision of column WATERTEMP_CHECK_0_0_01 changed from 3 to 2; ('apply_template') 07-Jan-2024: Descriptions of columns LOGGERID, PROGID, SITE_VISIT, EC_BRUSH, STAGE_RESET, WATER_SAMP, STAGE_HG, STAGE_INST_0_0_01, AIRTEMP_CHECK_150_0_01, AIRTEMP_MEAN_150_0_01, EC_CHECK, EC_INST_0_0_01, WATERTEMP_CHECK_0_0_01, WATERTEMP_INST_0_0_01 and VNOTCH_INST_0_0_01 edited; ('apply_template') 07-Jan-2024: added column 'Site' at position 1 ('addcol') 07-Jan-2024: converted units of 'EC_INST_0_0_01' column and 2 QA/QC flag criteria parameters from cmS cm^-1 to microS/cm ('unit_convert') 07-Jan-2024: Q/C flagging criteria applied for column(s) EC_INST_0_0_01, 'flags' field updated ('dataflag') 07-Jan-2024: documented flagged and missing values in columns PROGID, EC_BRUSH, STAGE_RESET, WATER_SAMP, STAGE_HG, AIRTEMP_CHECK_150_0_01, EC_CHECK, WATERTEMP_CHECK_0_0_01, VNOTCH_INST_0_0_01 and STAGE_HGTM as data set anomalies in the metadata ('add_anomalies') 07-Jan-2024: updated title ('newtitle') 07-Jan-2024: updated 1 metadata fields in the Dataset section(s) ('addmeta') 07-Jan-2024: updated title ('newtitle') 07-Jan-2024: updated 1 metadata fields in the Dataset section(s) ('addmeta') 07-Jan-2024: deleted column Date from the structure ('deletecols') 07-Jan-2024: added column 'Date' at position 2 ('addcol') 07-Jan-2024: flags for columns SiteID, SITE_VISIT, EC_BRUSH, STAGE_RESET, WATER_SAMP, STAGE_HG, STAGE_INST_0_0_01, AIRTEMP_CHECK_150_0_01, AIRTEMP_MEAN_150_0_01, EC_CHECK, EC_INST_0_0_01, WATERTEMP_CHECK_0_0_01, WATERTEMP_INST_0_0_01, VNOTCH_INST_0_0_01 and STAGE_HGTM converted to data columns, flag codes updated in metadata ('flags2cols') 07-Jan-2024: updated 6 metadata fields in the Data section(s) ('addmeta') 07-Jan-2024: updated 15 metadata fields in the Status, Data sections to reflect attribute metadata ('updatecols') 07-Jan-2024: parsed and formatted metadata ('listmeta') B. Variable Information 1. Variable Name: column 1. Site column 2. Date column 3. RecNum column 4. SiteID column 5. Flag_SiteID column 6. LOGGERID column 7. PROGID column 8. SITE_VISIT column 9. Flag_SITE_VISIT column 10. EC_BRUSH column 11. Flag_EC_BRUSH column 12. STAGE_RESET column 13. Flag_STAGE_RESET column 14. WATER_SAMP column 15. Flag_WATER_SAMP column 16. STAGE_HG column 17. Flag_STAGE_HG column 18. STAGE_INST_0_0_01 column 19. Flag_STAGE_INST_0_0_01 column 20. AIRTEMP_CHECK_150_0_01 column 21. Flag_AIRTEMP_CHECK_150_0_01 column 22. AIRTEMP_MEAN_150_0_01 column 23. Flag_AIRTEMP_MEAN_150_0_01 column 24. EC_CHECK column 25. Flag_EC_CHECK column 26. EC_INST_0_0_01 column 27. Flag_EC_INST_0_0_01 column 28. WATERTEMP_CHECK_0_0_01 column 29. Flag_WATERTEMP_CHECK_0_0_01 column 30. WATERTEMP_INST_0_0_01 column 31. Flag_WATERTEMP_INST_0_0_01 column 32. VNOTCH_INST_0_0_01 column 33. Flag_VNOTCH_INST_0_0_01 column 34. STAGE_HGTM column 35. Flag_STAGE_HGTM 2. Variable Definition: column 1. Site code column 2. Round off corrected corrected serial date column 3. RecNum column 4. SiteID column 5. QA/QC flags for SiteID (flagging criteria, where "x" is SiteID: ) column 6. Logger ID column 7. Program ID column 8. Did you visit the site? (1 = yes) column 9. QA/QC flags for Did you visit the site? (1 = yes) (flagging criteria, where "x" is SITE_VISIT: flag_notinarray(x,[NAN,1])="Q") column 10. Did you brush the EC probe? (1 = yes) column 11. QA/QC flags for Did you brush the EC probe? (1 = yes) (flagging criteria, where "x" is EC_BRUSH: flag_notinarray(x,[NAN,1])="Q", isnan(x)="M") column 12. Did you reset the PAT? (1 = yes) column 13. QA/QC flags for Did you reset the PAT? (1 = yes) (flagging criteria, where "x" is STAGE_RESET: flag_notinarray(x,[NAN,1])="Q", isnan(x)="M") column 14. Time water sample collected column 15. QA/QC flags for Time water sample collected (flagging criteria, where "x" is WATER_SAMP: x<0="Q", x>2400="Q", isnan(x)="M") column 16. Hook gauge reading (0.000 ft) column 17. QA/QC flags for Hook gauge reading (0.000 ft) (flagging criteria, where "x" is STAGE_HG: isnan(x)="M") column 18. Stage height column 19. QA/QC flags for Stage height (flagging criteria, where "x" is STAGE_INST_0_0_01: isnan(x)="M", flag_daterange(Date,{"07/17/2021 15:15:00","07/19/2021 15:40:00"})="Q", flag_daterange(Date,{"08/17/2021 11:25:00","08/24/2021 14:00:00"})="Q", flag_daterange(Date,{"06/18/2020 11:35:00","06/23/2020 07:50:00"})="Q") column 20. Manual air temperature check column 21. QA/QC flags for Manual air temperature check (flagging criteria, where "x" is AIRTEMP_CHECK_150_0_01: x<-35="I", x>55="I", isnan(x)="M") column 22. Average air temperature (305) column 23. QA/QC flags for Average air temperature (305) (flagging criteria, where "x" is AIRTEMP_MEAN_150_0_01: x<-35="I", x>55="I", isnan(x)="M", xair_FOURHI="Q", (AIRTEMP_MAX_150_0_01-AIRTEMP_MEAN_150_0_01)>1="Q", (AIRTEMP_MEAN_150_0_01-AIRTEMP_MIN_150_0_01)>1="Q", x>AIRTEMP_MAX_150_0_01="I", x=7000="I", isnan(x)="M", Date>=datenum("10/1/2015 12:00:00")&Date<=datenum("11/6/2015 12:00:00")="Q", Date>=datenum("04/15/2016 18:10:00")&Date<=datenum("04/18/2016 12:00:00")="X") column 28. Manual Water Temperature check column 29. QA/QC flags for Manual Water Temperature check (flagging criteria, where "x" is WATERTEMP_CHECK_0_0_01: x<-2="I", x>30="I", x<-1="Q", x>21="Q", isnan(x)="M") column 30. Instantaneous temperature of water from EC column 31. QA/QC flags for Instantaneous temperature of water from EC (flagging criteria, where "x" is WATERTEMP_INST_0_0_01: x<-2="I", x>30="I", x<-1="Q", x>21="Q", isnan(x)="M", xwater_FOURHI="Q", Date>=datenum("10/1/2015 12:00:00")&Date<=datenum("11/6/2015 12:00:00")="Q", Date>=datenum("7/30/2020 16:00:00")&Date<=datenum("08/17/2020 16:35:00")="Q", (WATERTEMP_MAX_0_0_01-WATERTEMP_INST_0_0_01)>0.5="Q", (WATERTEMP_INST_0_0_01-WATERTEMP_MIN_0_0_01)>0.5="Q", x>WATERTEMP_MAX_0_0_01="I", x1="Q", x<0="Q",flag_notinarray(x,[0,1])="Q") column 34. STAGE_HGTM column 35. QA/QC flags for STAGE_HGTM (flagging criteria, where "x" is STAGE_HGTM: ) 3. Units of Measurement: column 1. column 2. yyyy-MM-dd HH:mm:ss column 3. count column 4. column 5. none column 6. none column 7. none column 8. number column 9. none column 10. number column 11. none column 12. number column 13. none column 14. HHMM column 15. none column 16. ft column 17. none column 18. ft column 19. none column 20. deg c column 21. none column 22. deg c column 23. none column 24. uS/cm column 25. none column 26. microS/cm column 27. none column 28. deg c column 29. none column 30. deg c column 31. none column 32. number column 33. none column 34. column 35. none 4. Data Type a. Storage Type: column 1. string column 2. string column 3. integer column 4. floating-point column 5. string column 6. integer column 7. floating-point column 8. integer column 9. string column 10. integer column 11. string column 12. integer column 13. string column 14. integer column 15. string column 16. floating-point column 17. string column 18. floating-point column 19. string column 20. floating-point column 21. string column 22. floating-point column 23. string column 24. floating-point column 25. string column 26. floating-point column 27. string column 28. floating-point column 29. string column 30. floating-point column 31. string column 32. integer column 33. string column 34. floating-point column 35. string b. Variable Codes: Flag_EC_BRUSH: M = unspecified Flag_STAGE_RESET: M = unspecified Flag_WATER_SAMP: M = unspecified Flag_STAGE_HG: M = unspecified Flag_AIRTEMP_CHECK_150_0_01: I = invalid value (out of range), M = unspecified Flag_EC_CHECK: M = unspecified Flag_WATERTEMP_CHECK_0_0_01: I = invalid value (out of range), M = unspecified, Q = questionable value c. Numeric Range: column 1. (none) column 2. (none) column 3. 0 to 17 column 4. 101 to 101 column 5. (none) column 6. 115 to 115 column 7. 2108 to 19093 column 8. 1 to 1 column 9. (none) column 10. 1 to 1 column 11. (none) column 12. 1 to 1 column 13. (none) column 14. 720 to 1715 column 15. (none) column 16. 0.019 to 0.132 column 17. (none) column 18. 0.018 to 0.133 column 19. (none) column 20. -40 to 30.6 column 21. (none) column 22. 4.712 to 30.1 column 23. (none) column 24. -999 to 75.66 column 25. (none) column 26. 63.6066 to 76.2956 column 27. (none) column 28. -40 to 17.3 column 29. (none) column 30. 9.69 to 17.08 column 31. (none) column 32. (none) column 33. (none) column 34. (none) column 35. (none) d. Missing Value Code: NaN 5. Data Format a. Column Type: column 1. text column 2. text column 3. numerical column 4. numerical column 5. text column 6. numerical column 7. numerical column 8. numerical column 9. text column 10. numerical column 11. text column 12. numerical column 13. text column 14. numerical column 15. text column 16. numerical column 17. text column 18. numerical column 19. text column 20. numerical column 21. text column 22. numerical column 23. text column 24. numerical column 25. text column 26. numerical column 27. text column 28. numerical column 29. text column 30. numerical column 31. text column 32. numerical column 33. text column 34. numerical column 35. text b. Number of Columns: 35 c. Decimal Places: column 1. 0 column 2. 0 column 3. 0 column 4. 2 column 5. 0 column 6. 0 column 7. 1 column 8. 0 column 9. 0 column 10. 0 column 11. 0 column 12. 0 column 13. 0 column 14. 0 column 15. 0 column 16. 4 column 17. 0 column 18. 4 column 19. 0 column 20. 2 column 21. 0 column 22. 3 column 23. 0 column 24. 4 column 25. 0 column 26. 4 column 27. 0 column 28. 2 column 29. 0 column 30. 3 column 31. 0 column 32. 0 column 33. 0 column 34. 0 column 35. 0 6. Logical Variable Type: column 1. nominal (none) column 2. datetime (none) column 3. nominal (discrete) column 4. data (unspecified) column 5. coded value (none) column 6. nominal (discrete) column 7. nominal (continuous) column 8. data (discrete) column 9. coded value (none) column 10. data (discrete) column 11. coded value (none) column 12. data (discrete) column 13. coded value (none) column 14. data (discrete) column 15. coded value (none) column 16. data (continuous) column 17. coded value (none) column 18. data (continuous) column 19. coded value (none) column 20. data (continuous) column 21. coded value (none) column 22. data (continuous) column 23. coded value (none) column 24. data (continuous) column 25. coded value (none) column 26. data (continuous) column 27. coded value (none) column 28. data (continuous) column 29. coded value (none) column 30. data (continuous) column 31. coded value (none) column 32. data (discrete) column 33. coded value (none) column 34. data (continous) column 35. coded value (none) 7. Flagging Criteria: column 1. none column 2. none column 3. x<0="I" column 4. none column 5. none column 6. flag_notinarray(x,[101,115])="I" column 7. flag_valuechange(x,0.1,0.1,1)="P" column 8. flag_notinarray(x,[NAN,1])="Q" column 9. none column 10. flag_notinarray(x,[NAN,1])="Q";isnan(x)="M" column 11. none column 12. flag_notinarray(x,[NAN,1])="Q";isnan(x)="M" column 13. none column 14. x<0="Q";x>2400="Q";isnan(x)="M" column 15. none column 16. isnan(x)="M" column 17. none column 18. isnan(x)="M";flag_daterange(col_Date,{"07/17/2021 15:15:00","07/19/2021 15:40:00"})="Q";flag_daterange(col_Date,{"08/17/2021 11:25:00","08/24/2021 14:00:00"})="Q";flag_daterange(col_Date,{"06/18/2020 11:35:00","06/23/2020 07:50:00"})="Q" column 19. none column 20. x<-35="I";x>55="I";isnan(x)="M" column 21. none column 22. x<-35="I";x>55="I";isnan(x)="M";xcol_air_FOURHI="Q";(col_AIRTEMP_M AX_150_0_01-col_AIRTEMP_MEAN_150_0_01)>1="Q"; (col_AIRTEMP_MEAN_150_0_01-col_AIRTEMP_MIN_150_0_01)>1="Q"; x>col_AIRTEMP_MAX_150_0_01="I"; x=7000="I";isnan(x)="M";col_Date>=datenum("10/1/2015 12:00:00")&col_Date<=datenum("11/6/2015 12:00:00")="Q";col_Date>=datenum("04/15/2016 18:10:00")&col_Date<=datenum("04/18/2016 12:00:00")="X" column 27. none column 28. x<-2="I";x>30="I";x<-1="Q";x>21="Q";isnan(x)="M" column 29. none column 30. x<-2="I";x>30="I";x<-1="Q";x>21="Q";isnan(x)="M";xcol_water_FOUR HI="Q";col_Date>=datenum("10/1/2015 12:00:00")&col_Date<=datenum("11/6/2015 12:00:00")="Q";col_Date>=datenum("7/30/2020 16:00:00")&col_Date<=datenum("08/17/2020 16:35:00")="Q";(col_WATERTEMP_MAX_0_0_01-col_WATERTEMP_INST_0_0_01)>0.5="Q"; (col_WATERTEMP_INST_0_0_01-col_WATERTEMP_MIN_0_0_01)>0.5="Q"; x>col_WATERTEMP_MAX_0_0_01="I"; x1="Q";x<0="Q",flag_notinarray(x,[0,1])="Q" column 33. none column 34. none column 35. none C. Data Anomalies: The value of one record in PROGID was flagged as P (undefined flag) for date 07/26/2018. Values of 16 records in EC_BRUSH were flagged as M (undefined flag) for dates: 07/26/2018, 08/06/2018-08/21/2018, 08/28/2018-09/11/2018, 09/17/2018, 09/25/2018. Values of 16 records in EC_BRUSH are missing for dates: 07/26/2018, 08/06/2018-08/21/2018, 08/28/2018-09/11/2018, 09/17/2018, 09/25/2018. Values of 14 records in STAGE_RESET were flagged as M (undefined flag) for dates: 07/26/2018-08/06/2018, 08/21/2018, 08/28/2018, 09/04/2018-09/11/2018, 09/17/2018, 09/25/2018. Values of 14 records in STAGE_RESET are missing for dates: 07/26/2018-08/06/2018, 08/21/2018, 08/28/2018, 09/04/2018-09/11/2018, 09/17/2018, 09/25/2018. Values of 13 records in WATER_SAMP were flagged as M (undefined flag) for dates: 07/26/2018-08/06/2018, 08/21/2018, 08/28/2018, 09/04/2018-09/11/2018, 09/17/2018, 09/17/2018-09/25/2018. Values of 13 records in WATER_SAMP are missing for dates: 07/26/2018-08/06/2018, 08/21/2018, 08/28/2018, 09/04/2018-09/11/2018, 09/17/2018, 09/17/2018-09/25/2018. Values of 11 records in STAGE_HG were flagged as M (undefined flag) for dates: 07/26/2018-08/01/2018, 08/06/2018, 08/21/2018, 08/28/2018, 09/04/2018, 09/17/2018. Values of 11 records in STAGE_HG are missing for dates: 07/26/2018-08/01/2018, 08/06/2018, 08/21/2018, 08/28/2018, 09/04/2018, 09/17/2018. Values of 2 records in AIRTEMP_CHECK_150_0_01 were flagged as I (invalid value (out of range)) for date 07/26/2018. Values of 14 records in AIRTEMP_CHECK_150_0_01 were flagged as M (undefined flag) for dates: 07/26/2018, 08/01/2018, 08/06/2018, 08/21/2018, 08/28/2018-09/11/2018, 09/17/2018-09/25/2018. Values of 14 records in AIRTEMP_CHECK_150_0_01 are missing for dates: 07/26/2018, 08/01/2018, 08/06/2018, 08/21/2018, 08/28/2018-09/11/2018, 09/17/2018-09/25/2018. Values of 14 records in EC_CHECK were flagged as M (undefined flag) for dates: 07/26/2018, 08/01/2018, 08/06/2018, 08/21/2018, 08/28/2018-09/11/2018, 09/17/2018-09/25/2018. Values of 14 records in EC_CHECK are missing for dates: 07/26/2018, 08/01/2018, 08/06/2018, 08/21/2018, 08/28/2018-09/11/2018, 09/17/2018-09/25/2018. Values of 2 records in WATERTEMP_CHECK_0_0_01 were flagged as I (invalid value (out of range)) for date 07/26/2018. Values of 14 records in WATERTEMP_CHECK_0_0_01 were flagged as M (undefined flag) for dates: 07/26/2018, 08/01/2018, 08/06/2018, 08/21/2018, 08/28/2018-09/11/2018, 09/17/2018-09/25/2018. Values of 14 records in WATERTEMP_CHECK_0_0_01 are missing for dates: 07/26/2018, 08/01/2018, 08/06/2018, 08/21/2018, 08/28/2018-09/11/2018, 09/17/2018-09/25/2018. Values of 20 records in VNOTCH_INST_0_0_01 are missing for dates: 07/26/2018-09/25/2018. Values of 20 records in STAGE_HGTM are missing for dates: 07/26/2018-09/25/2018. V. Supplemental Descriptors A. Data Acquisition 1. Data Forms: 2. Form Location: 3. Data Entry Validation: B. Quality Assurance/Quality Control Procedures: C. Supplemental Materials: D. Computer Programs: E. Archival Practices: F. Publications: G. History of Data Set Usage 1. Data Request History: 2. Data Set Update History: 3. Review History: 4. Questions and Comments from Users: