Downloads:
|
Data Table: cs2met_113_a_5min_2016 (Main data table, 105409 records)
Access: Public
Metadata: Text (ESA FLED)
Data Files:
GCE Data Toolbox File [3817kb]
Column List:
Column |
Name |
Units |
Type |
Description (show)
|
1 |
Site |
|
string |
Site code |
2 |
Date |
serial number |
floating-point |
TmStamp |
3 |
LOGGERID |
none |
integer |
LOGGERID |
4 |
PROGID |
none |
floating-point |
Program ID of program |
5 |
AIRTEMP_MEAN_150_0_03 |
deg c |
floating-point |
Air temperature from HC2S3 |
6 |
Flag_AIRTEMP_MEAN_150_0_03 |
none |
string |
QA/QC flags for Air temperature from HC2S3 (flagging criteria, where "x" is AIRTEMP_MEAN_150_0_03: x<=-35="I", x>50="I", flag_valuechange(x,6.5,6.5,1) ="V", flag_valuechange(x,8,8,1) ="Q", isnan(x)="M", x<FOURLO="Q", x>FOURHI="Q", Date<=datenum("4/08/2015 12:00:00")="I") |
7 |
RELHUM_MEAN_150_0_03 |
percent |
floating-point |
Relative humidity from HC2S3 |
8 |
Flag_RELHUM_MEAN_150_0_03 |
none |
string |
QA/QC flags for Relative humidity from HC2S3 (flagging criteria, where "x" is RELHUM_MEAN_150_0_03: x<9="I", isnan(x)="M") |
9 |
DEWPT_MEAN_150_0_03 |
deg c |
floating-point |
Dew point from HC2S3 |
10 |
Flag_DEWPT_MEAN_150_0_03 |
none |
string |
QA/QC flags for Dew point from HC2S3 (flagging criteria, where "x" is DEWPT_MEAN_150_0_03: AIRTEMP_MEAN_150_0_04<=-35="I", AIRTEMP_MEAN_150_0_04>50="I", flag_valuechange(AIRTEMP_MEAN_150_0_04,6.5,6.5,1) ="V", flag_valuechange(AIRTEMP_MEAN_150_0_04,8,8,1) ="Q", isnan(RELHUM_MEAN_150_0_04)="M", isnan(AIRTEMP_MEAN_150_0_04)="M", AIRTEMP_MEAN_150_0_04<FOURLO="Q", AIRTEMP_MEAN_150_0_04>FOURHI="Q", isnan(x)="M") |
11 |
BATTERY_AVG |
volts |
floating-point |
Battery supply voltage |
12 |
Flag_BATTERY_AVG |
none |
string |
QA/QC flags for Battery supply voltage (flagging criteria, where "x" is BATTERY_AVG: x<0="I", x<12="L", x>15="H", isnan(x)="M") |
13 |
AIRTEMP_MAX_150_0_03 |
deg c |
floating-point |
Air temperature from HC2S3 |
14 |
Flag_AIRTEMP_MAX_150_0_03 |
none |
string |
QA/QC flags for Air temperature from HC2S3 (flagging criteria, where "x" is AIRTEMP_MAX_150_0_03: x<=-35="I", x>50="I", flag_valuechange(x,6.5,6.5,1) ="V", flag_valuechange(x,8,8,1) ="Q", isnan(x)="M", x<FOURLO="Q", x>FOURHI="Q") |
15 |
RELHUM_MAX_150_0_03 |
percent |
floating-point |
Relative humidity from HC2S3 |
16 |
Flag_RELHUM_MAX_150_0_03 |
none |
string |
QA/QC flags for Relative humidity from HC2S3 (flagging criteria, where "x" is RELHUM_MAX_150_0_03: x<9="I", isnan(x)="M") |
17 |
DEWPT_MAX_150_0_03 |
deg c |
floating-point |
Dew point from HC2S3 |
18 |
Flag_DEWPT_MAX_150_0_03 |
none |
string |
QA/QC flags for Dew point from HC2S3 (flagging criteria, where "x" is DEWPT_MAX_150_0_03: AIRTEMP_MEAN_150_0_04<=-35="I", AIRTEMP_MEAN_150_0_04>50="I", flag_valuechange(AIRTEMP_MEAN_150_0_04,6.5,6.5,1) ="V", flag_valuechange(AIRTEMP_MEAN_150_0_04,8,8,1) ="Q", isnan(RELHUM_MEAN_150_0_04)="M", isnan(AIRTEMP_MEAN_150_0_04)="M", AIRTEMP_MEAN_150_0_04<FOURLO="Q", AIRTEMP_MEAN_150_0_04>FOURHI="Q", isnan(x)="M") |
19 |
AIRTEMP_MIN_150_0_03 |
deg c |
floating-point |
Air temperature from HC2S3 |
20 |
Flag_AIRTEMP_MIN_150_0_03 |
none |
string |
QA/QC flags for Air temperature from HC2S3 (flagging criteria, where "x" is AIRTEMP_MIN_150_0_03: x<=-35="I", x>50="I", flag_valuechange(x,6.5,6.5,1) ="V", flag_valuechange(x,8,8,1) ="Q", isnan(x)="M", x<FOURLO="Q", x>FOURHI="Q") |
21 |
RELHUM_MIN_150_0_03 |
percent |
floating-point |
Relative humidity from HC2S3 |
22 |
Flag_RELHUM_MIN_150_0_03 |
none |
string |
QA/QC flags for Relative humidity from HC2S3 (flagging criteria, where "x" is RELHUM_MIN_150_0_03: x<9="I", isnan(x)="M") |
23 |
DEWPT_MIN_150_0_03 |
deg c |
floating-point |
Dew point from HC2S3 |
24 |
Flag_DEWPT_MIN_150_0_03 |
none |
string |
QA/QC flags for Dew point from HC2S3 (flagging criteria, where "x" is DEWPT_MIN_150_0_03: AIRTEMP_MEAN_150_0_04<=-35="I", AIRTEMP_MEAN_150_0_04>50="I", flag_valuechange(AIRTEMP_MEAN_150_0_04,6.5,6.5,1) ="V", flag_valuechange(AIRTEMP_MEAN_150_0_04,8,8,1) ="Q", isnan(RELHUM_MEAN_150_0_04)="M", isnan(AIRTEMP_MEAN_150_0_04)="M", AIRTEMP_MEAN_150_0_04<FOURLO="Q", AIRTEMP_MEAN_150_0_04>FOURHI="Q", isnan(x)="M") |
25 |
FOURLO |
deg c |
floating-point |
Air temperature 4*std lower of mean air temperature (lower bound) |
26 |
Flag_FOURLO |
none |
string |
QA/QC flags for Air temperature 4*std lower of mean air temperature (lower bound) (flagging criteria, where "x" is FOURLO: x>FOURHI="I", x>MEAN="I", x>MEDIAN="I") |
27 |
FOURHI |
deg c |
floating-point |
Air temperature 4*std greater than mean air temperature |
28 |
Flag_FOURHI |
none |
string |
QA/QC flags for Air temperature 4*std greater than mean air temperature (flagging criteria, where "x" is FOURHI: x<FOURLO="I", X<MEAN="I", x<MEDIAN="I") |
29 |
SATVP_MEAN_150_0_03 |
mb |
floating-point |
Saturation vapor pressure or vapor pressure at air temp. es = 6.1078 .* exp((17.269 .* Tair) ./ (237.3 + Tair)) |
30 |
Flag_SATVP_MEAN_150_0_03 |
none |
string |
QA/QC flags for Saturation vapor pressure or vapor pressure at air temp. es = 6.1078 .* exp((17.269 .* Tair) ./ (237.3 + Tair)) (flagging criteria, where "x" is SATVP_MEAN_150_0_03: manual) |
31 |
VAP_MEAN_150_0_03 |
mb |
floating-point |
Actual vapor pressure or vapor pressure at dewpoint temp. ea = 6.1078 .* exp((17.269 .* Tdew) ./ (237.3 + Tdew)) |
32 |
Flag_VAP_MEAN_150_0_03 |
none |
string |
QA/QC flags for Actual vapor pressure or vapor pressure at dewpoint temp. ea = 6.1078 .* exp((17.269 .* Tdew) ./ (237.3 + Tdew)) (flagging criteria, where "x" is VAP_MEAN_150_0_03: manual) |
33 |
VPD_MEAN_150_0_03 |
mb |
floating-point |
Vapor pressure deficit. vpd = es - (Rh .* es ./ 100) |
34 |
Flag_VPD_MEAN_150_0_03 |
none |
string |
QA/QC flags for Vapor pressure deficit. vpd = es - (Rh .* es ./ 100) (flagging criteria, where "x" is VPD_MEAN_150_0_03: manual) |
|