Snow Lysimeter Sites

Site Maps

---------------------------------------------------------------

CENMET (Snow Lysimeter)

Site description: Clearcut Nov 1986, natural regeneration

Latitude: 44-14-36 Longitude: 122- 8-30 Elevation (MSL): 1018 meters

Aspect: 260 degrees Slope: 12 degrees

Measurement period: 19951130 - Present

Comments:

Daily Variables:
30 Nov 1995 to Present :
Daily snow lysimeter runoff

Fine Resolution Variables:
30 Nov 1995 to Present :
5 minute snow lysimeter runoff

Notes: Tipping bucket tips are summarized by 5 minute intervals
on a CR10 recorder. An event counter totals the number of tips
over the collection period as a check.


PROBE 01:

---------------------------------------------------------------

H15MET (Snow Lysimeter)

Site description: Old-growth opening/Road junction

Latitude: 44-15-51 Longitude: 122-10-26 Elevation (MSL): 922 meters

Aspect: 240 degrees Slope: 15 degrees

Measurement period: 19901001 - Present

Comments:

Daily Variables:
01 Oct 1990 to Present :
Daily snow lysimeter runoff

Fine Resolution Variables:
01 Oct 1990 to 12 Mar 1992:
15 minute snow lysimeter runoff

12 Mar 1992 to Present :
5 minute snow lysimeter runoff

Notes: Tipping bucket tips were recorded as events on an A-35 chart
until 12 Mar 1992. The events were digitized from the chart during this period.
An event counter totaled the number of tips over the collection
period as a check. After 12 Mar 1992, tipping bucket tips are
summarized by 5 minute intervals on a CR10 recorder.
CR10, Samples every 10 seconds

PROBE 01:

---------------------------------------------------------------

UPLMET (Snow Lysimeter)

Site description: Clearcut 1965

Latitude: 44-12-26 Longitude: 122- 7-10 Elevation (MSL): 1294 meters

Aspect: 72 degrees Slope: 13 degrees

Measurement period: 19941026 - Present

Comments:

Daily Variables:
26 Oct 1994 to Present :
Daily snow lysimeter runoff

Fine Resolution Variables:
26 Oct 1994 to Present :
5 minute snow lysimeter runoff

Notes: Tipping bucket tips are summarized by 5 minute intervals
on a CR10 recorder. An event counter totals the number of tips
over the collection period as a check.


PROBE 01: